Environmental Climate High and Low Temperature Test Chamber (HZ-2012A)

Product Details
Basic Info
Model NO.: HZ-2012A
Weight: 500-1000Kg
Certificate: ASTM, Cns, IEC, JIS, Aatcc, DIN, Fed Test, Bs, SAE
Control Temperature: ±2 Degree
Heating Time: Rt to 150 About 35min
Device Noise: Below 75dB.
Expansion: Heat Reach 300 Deg, Cold Reach -100 Deg
Trademark: lixian
Origin: China
Type: Environmental Test Machine
Power Source: AC220V
Temperature Range: -70~150deg
Resolution: 0.01 Degree
Cooling Time: Rt to -40 Degree About 50min
Testing Region: 50cm(W)*50cm(H)*50cm(D) Custom
Service: OEM, Oversea Service
Specification: According the requirements
HS Code: 90248000
Product Description
Environmental Climate High and Low Temperature Test Chamber HZ-2012
Equipment summary:
Cold and thermal shock test chamber used to test the change of material under extremely high temperature and extremely low temperature environment that continue alternation in the shortest time, Testing the chemical changes or physical damage of material caused by the thermal expansion and contraction. Testing box divided two parts, one is high-temperature region, another is low-temperature region, the testing sample placed on the moving basket, using unique heat storage and cool storage, the cylinder taking basket moves up and down in the hot and cold region to complete the hot and cold temperature impact testing; Applied to test the material, including metal, plastic, rubber, electronics...And other materials, it can be used as a basis for improvement of their products.
Corresponding standard:
1 GB/T2423.1-1989 low-temperature testing method
2 GB/T2423.2-1989 high-temperature testing method
3 GB/T2423.22-1989 change temperature test
4 GJB150.5-86 temperature impact test
5 GJB360.7-87 temperature impact test
6 GJB367.2-87 405 temperature impact test
Applicable industries:
Cold and thermal shock test chamber widely used in aviation, military, ships, electrical, electronics, instruments and meters; Medical equipment; Civilian nuclear energy; Colleges and universities; Research laboratories; Commodity inspection, arbitration, technical supervision departments; Building materials ceramic; Petroleum and chemical products, machine and spare parts.
Equipment summary:
Cold and thermal shock test chamber used to test the change of material under extremely high temperature and extremely low temperature environment that continue alternation in the shortest time, Testing the chemical changes or physical damage of material caused by the thermal expansion and contraction. Testing box divided two parts, one is high-temperature region, another is low-temperature region, the testing sample placed on the moving basket, using unique heat storage and cool storage, the cylinder taking basket moves up and down in the hot and cold region to complete the hot and cold temperature impact testing; Applied to test the material, including metal, plastic, rubber, electronics...And other materials, it can be used as a basis for improvement of their products.
Corresponding standard:
1 GB/T2423.1-1989 low-temperature testing method
2 GB/T2423.2-1989 high-temperature testing method
3 GB/T2423.22-1989 change temperature test
4 GJB150.5-86 temperature impact test
5 GJB360.7-87 temperature impact test
6 GJB367.2-87 405 temperature impact test
Applicable industries:
Cold and thermal shock test chamber widely used in aviation, military, ships, electrical, electronics, instruments and meters; Medical equipment; Civilian nuclear energy; Colleges and universities; Research laboratories; Commodity inspection, arbitration, technical supervision departments; Building materials ceramic; Petroleum and chemical products, machine and spare parts.
Parameter | |
Model | HZ-2012A High and Low Temperature Thermal Shock Test Chamber |
Temperature range | A.high-temperature : +60 degree to +150 degree |
B.low-temperature : -10 degree to -40 degree | |
Control temperature | ±2 degree |
Resolution | 0.01 degree |
Heating time at high-temperature region | From RT to 150 about 35min (RT is from 5 degree to 30 degree). |
Cooling time at low-temperature region | From RT to -40 degree about 50min (RT is from 5 degree to 30 degree) |
Moving time and temperature recover time | A. testing bastet moving from high-temperature to low-temperature spend 10sec |
B.after exchanging the temperature,the tempreature recovery time: 3min to 5min (Stabilization time ≥ 30min) | |
Device noise | Below 75dB. |
Sample weight | 10Kg |
Testing region(hot and cold) | 50cm(W)*50cm(H)*50cm(D) |
Outside size | 140cm(W)*180cm(H)*142cm(D) |
Testing basket size | 30cm(W)*40cm(H)*30cm(D) |
Inside material | SUS#304 Cold-Heat-resistant stainless steel |
Outside material | SUS#304 Cold-Heat-resistant stainless steel |
Insolution material | High-density glass wool and high strength PU foam insulation |
Anti-sweat structure | insulation layer and door micro-thermal anti-sweat |
Expansion | Heat reach 300 degree,cold reach -100 degree |
Hot Tags: environmental climate high and low temperature test chamber (hz-2012a), manufacturers, suppliers, factory, wholesale, cheap, best, buy